Data Analytics, Digital Twin Refinement, Prediction.
AMOG developed high fidelity digital twins of two 40 year old reclaimers, verified by measurements of stresses on the prototype during typical operations. The analysis, digital twin verification and prediction of the progression of future fatigue damage provided a basis for the identification of remedial measures. For the client, this allowed the machine service life to be extended for an additional 20 years, enabling the deferment of significant capital expenditure. The risk-based inspection regime also delivered potential to reduce downtime risk below the required threshold.
Edge Devices: Strain gauges
Bridge/Comms: Data logger